FAST & FLUID MANAGEMENTBlendorama series IIENGLISH
p9© Fast & Fluid Management, Blendorama series II> >(3) Firmly push the canisterand connecting tube into theremote bracket and pumpassembly.
p10© Fast & Fluid Management, Blendorama series IIOperationA - First time operationStep 4 - Preparing the dispenser> >Ensure that the machin
p11© Fast & Fluid Management, Blendorama series IIStep 2 - Purging the pumps> >Set the gauge or gauges ofeach pump to its halfwaypoint by op
p12© Fast & Fluid Management, Blendorama series II> >Push the red pump handledown fully to dispensecolorant into the cupRelease the valve le
p13© Fast & Fluid Management, Blendorama series IIB - General use of the dispenserStep 1 - Select the color, base and can size> >Identify th
p14© Fast & Fluid Management, Blendorama series IIStep 3 - Bring canister to the correct position>Depress and hold the detentlever to release t
p15© Fast & Fluid Management, Blendorama series IIStep 4 - Set the Gauges> >According to the settingrequired, operate the springloaded butto
p16© Fast & Fluid Management, Blendorama series IIStep 6 - Discharge the pump> >While still holding the pumphandle in the raisedposition, pu
p17© Fast & Fluid Management, Blendorama series IIPreventitive maintenanceA - Do’s & Don’tsDOKeep the machine clean and display advertising pr
p18© Fast & Fluid Management, Blendorama series II>Clean the nozzle using warmsoapy waterRefit the nozzle and dispense asmall amount of coloran
p1© Fast & Fluid Management, Blendorama series II
p19© Fast & Fluid Management, Blendorama series IIC - Weekly maintenanceIf the dispenser is not used on a regular daily basis, the following proce
p20© Fast & Fluid Management, Blendorama series IID - Periodic maintenanceThis maintenance should be carried out every 3 to 6 months dependingupon
p21© Fast & Fluid Management, Blendorama series IIGeneral maintenanceA - Metalcal replacement (Models 22/23 XC)Before replacing the metalcals, cal
p22© Fast & Fluid Management, Blendorama series II> >(7) Once in position, pressthe metalcal firmly onto thegauge, ensuring it adheresto the
p23© Fast & Fluid Management, Blendorama series II> >(4) Mark a line on the blackgauge, level with the top ofthe red handle. Use a finefelt
p24© Fast & Fluid Management, Blendorama series IIC - Metalcal replacement (Models 53 XB)Before replacing the metalcals, calibrate the plungers as
p25© Fast & Fluid Management, Blendorama series II> >(7) Once in position, pressthe metalcal firmly onto thegauge, ensuring it adheresto the
p26© Fast & Fluid Management, Blendorama series IID - Metalcal replacement (Models 53 XD/XE)Before replacing the metalcals, calibrate the plungers
p27© Fast & Fluid Management, Blendorama series II> >(7) Once in position, pressthe metalcal firmly onto thegauge, ensuring it adheresto the
p28© Fast & Fluid Management, Blendorama series IIE - Replacement of Piston Seals (Models 22/23 XC)> >(1) Loosen both grubscrewsin the cylin
p2© Fast & Fluid Management, Blendorama series II Table of ContentsBlendorama series II manual (EN) 3 Introduction, Conditions of Sale & Wa
p29© Fast & Fluid Management, Blendorama series IIF - Replacement of Piston Seals (Models 22/23 XD/XE)Step 1 - Replacement of the inner piston>
p30© Fast & Fluid Management, Blendorama series IIStep 2 - Replacement of the outer piston> >(1) Using two spanners,carefully undo the lower
p31© Fast & Fluid Management, Blendorama series IIG - Replacement of Piston Seals (Models 53 XB/XD/XE)Step 1 - Replacement of the inner piston>
p32© Fast & Fluid Management, Blendorama series IIStep 2 - Replacement of the outer piston> >(4) Fit the outer pistonassembly tool over the
p33© Fast & Fluid Management, Blendorama series IIH - Pump Calibration (Models 22/23 XC)Recalibration of the pump is necessary if the original gau
p34© Fast & Fluid Management, Blendorama series III - Pump Calibration (Models 22/23 XD/XE)Recalibration of the pump is necessary if the original
p35© Fast & Fluid Management, Blendorama series II>(5) Using the Allen key, undo thecalibration grubscrew in the red pumphandle until free mov
p36© Fast & Fluid Management, Blendorama series IIJ - Pump Calibration (Models 53 XB/XD/XE)Recalibration of the pump is necessary if either of the
p37© Fast & Fluid Management, Blendorama series IIStep 2 - Inner pump calibration>(1) Calibrate the inner pump by loweringred pump handle full
p38© Fast & Fluid Management, Blendorama series IITroubleshootingA - IntroductionBefore calling your machine supplier or Service Department, pleas
p3© Fast & Fluid Management, Blendorama series IIBlendorama series II manual (EN)Introduction, Conditions of Sale & WarrantyA - IntroductionBy
p39© Fast & Fluid Management, Blendorama series IIService AgentsA - Service AgentsFor all service and repairs on Fast & Fluid Management produ
p40© Fast & Fluid Management, Blendorama series IISpecificatiesNumber of canisters Up to 24Canister sizes 22/23 XC/XD/XE 1.75L Single canisters
p41© Fast & Fluid Management, Blendorama series IIWiring diagramA - Electrical wiring diagram – Twin Timer VersionB - Electrical wiring diagram –
p42© Fast & Fluid Management, Blendorama series II
© Fast & Fluid Management, 2005www.Fast-Fluid.com
p4© Fast & Fluid Management, Blendorama series II5. Limitation of LiabilitySubject to Paragraph 6 of these terms and conditions and in particular
p5© Fast & Fluid Management, Blendorama series II6.6 Warranty Exclusions Subject to sub-paragraph 6.7 hereof this Warranty does not extend and
p6© Fast & Fluid Management, Blendorama series IISafety instructionsA - General safety instructionsAttention! Before installing the equipment, ple
p7© Fast & Fluid Management, Blendorama series IIInstallationA - Unpacking the dispenserThe box(es) you have received contain:1 x Machine Base Ass
p8© Fast & Fluid Management, Blendorama series IIB - Installing the canistersPlease note that this procedure is used for all canister sizes, altho
Comments to this Manuals