Technische Daten X-Smart V 1.2
27
6.7 Schaltplan
5
5
4
4
3
3
2
2
1
1
D D
C C
B B
A A
USB to PC
24VDC
Powersu pply
RESETDIPSW.
1234
(OPTION)
Thursday, April 17, 2014
0
XSmart
1.0 <revdate0> <drawn0>
First production version
Emergency in powerline
Corrected emergency, is now double pole.
Removed e-switch jumper, is dipsw.setting now.
<Filename>
17-4-20142.02
NvB
NvB
NvB
21-1-2013
2.0
3-4-20132.01
2.02
Revnr.
Sheet
Title
Date Drawn Remarks
Filename
FAST & FLUID
Version
The Netherlands
2170 AE Sassenheim
PO Box 220
Hub v. Doorneweg 31
© Fast & FLuid
Cable, Agiation
Cable, Agiation
Cansensor
Cansensor
Cable, Valve
Cable, Valve
Cable, Turntable
Cable, Turntable
RED
BLUE
BLUE
BLACK
ORANGE
YELLOW
BROWN
BLUE
BROWN
BLUE
BROWN
M12
VALVE MOTOR
S1
MACHINE STOP
1
2
3
4
M1
4P-STEPPERMOTOR
M6
TURNTABLE MOTOR
S3
CANSENSOR
M5
AGITATION MOTOR